Phase 2 Proposal Instructions for Cycle 10 | ||||
|
13.4 Mode = ACQ
Configuration = NIC2
This mode requests the NICMOS flight software to locate the brightest target in the acquisition aperture of camera 2 (one quarter of the full NIC2 FOV, or 9.6x 9.6 arcsec) and place it behind the coronographic spot of camera 2. It is only necessary as a preparation for coronography with the NIC2-CORON aperture. Two images will be taken and downlinked, each with a single non-destructive readout at the beginning and the end of the exposure. Two each of background and lamp-on exposures will be taken to locate the coronographic hole.
13.4.1 Aperture or FOV
The NIC2ÐACQ aperture must be used in this Mode.
13.4.2 Spectral Elements
Use any in Table13.5: Spectral Elements for the NICMOS for the NIC2 configuration.
13.4.3 Wavelength
The Wavelength parameter is not required for NICMOS observations and should be left blank.
13.4.4 Optional Parameters
There are no Optional Parameters in this Mode.
13.4.5 Number of Iterations
Always enter 1. However, two exposures of the duration given in Time_Per_Exposure will be executed, for purposes of onboard cosmic ray elimination by the NICMOS flight software.
13.4.6 Time Per Exposure
Exposure times in ACQ Mode are quantized. The exposure consists of an initial readout, followed by a period of data accumulation, followed by a final readout. The Time_Per_Exposure (in seconds) refers to the total integration time, which begins at the start of the initial readout and ends at the start of the final readout. The NICMOS Timing Pattern Generator (TPG) uses a list of discrete values for the time between readouts (TPG_TIME), which is given in Table13.3: Quantized Legal NICMOS TPG Expose Times. The specified exposure time should be one of a set of possible values allowed by the following formula:
Time_Per_Exposure = TPG_TIME + 0.228
If the exposure time entered by the user is not one of the values allowed by the above formula, it will be reduced to the next lowest legal value. It is illegal to specify an exposure time below the minimum of 0.228 seconds.
13.4.7 Special Requirements
Science exposures associated with this acquisition must be identified as part of the <exposureÐlist> and must use the NIC2 configuration and the coronographic aperture NIC2ÐCORON.
The Special Requirement PARallel WITH is not allowed in this Mode.
Space Telescope Science Institute http://www.stsci.edu Voice: (410) 338-1082 help@stsci.edu |