17.3 SMOV2 Testing and Calibration


The primary goal of the Second Servicing Mission's Orbital Verification (SMOV2) was the timely commissioning of the HST observatory for normal science operations. For STIS, just installed at this time, this included testing the focus (internal and external), verifying the target acquisition procedures, monitoring instrument stability (both in terms of image motions and sensitivity), and measuring selected characteristics: plate scales, slit throughputs, line spread functions, etc. SMOV2 observations were complete by the summer of 1997. Most of the results of the calibrations were presented in the 1997 HST Calibration Workshop. A high level summary was provided in the Kimble et al. (1998, ApJ, 492, L83) paper on STIS on-orbit performance. For an update including early Cycle 7 calibration, see also Baum et al., 1998, SPIE, 3356, 271. Brief descriptions of the SMOV2 proposals are given in Table 17.1. Data from calibration proposals are non-proprietary, and can be obtained from the archive with the proposal IDs listed in the table.


Table 17.1: STIS SMOV2 Proposals  
ID Title
7058 STIS Memory Load and Dump
7059 Science Data Buffer Check with Self-Test
7061 CCD Functional
7062 CCD Temperature Set Point Determination
7063, 7064 STIS SMOV Contamination Monitor
7065 STIS to FGS Alignment
7066 STIS Acquisition Aperture and Slit Location
7067 STIS CCD Point Source Acquisition
7068 STIS CCD Diffuse Source Acquisition
7070 STIS CCD Coronagraphic Acquisition
7071 CCD Target Centering
7073 CCD Peakdowns for Coronagraphic Acquisition
7075 STIS Corrector Alignment, Coarse
7076 STIS Corrector Alignment, Fine
7077, 7078 Spectroscopic Mode Image Quality
7079, 7080 Camera Mode Image Quality
7081, 7082 Repeatability of Image Positions for STIS Modes
7083, 7084 Verification of Optical Format of STIS Modes
7085, 7086 STIS Slit to Detector Internal Stability
7087 OTA-STIS Pointing and Throughput Stability
7088, 7089 Occulting Bar Scattered Light
7090 PSF measurement for MAMAs
7091 STIS Pixel-To-Pixel Response Stability
7092 CCD Dark Rate and Read Noise
7093 Dark Measurement for MAMAs
7094, 7096 STIS Sensitivity On-Axis
7095, 7097 STIS Sensitivity (Vignetting)
7098 MAMA Flat Field Uniformity
7099 CCD Flat Field Stability
7100 SMOV Slit Transmission
7101 SMOV Slit Transmission
7103 STIS Mechanism Mini-Functional
7104 STIS Onboard Doppler Processing Checkout
7105 MAMA Turn-On
7106 STIS MAMA Fold Distribution
7107 STIS CCD Hot Pixel Annealing
7108 STIS MAMA Time Tag Mode
7131, 7132 STIS Imaging Mode Geometric Distortion
7133 STIS to FGS alignment
7142 CCD Flat Field Monitoring
7143 CCD Internal Image stability with LVPS cycling
7144 STIS Thermal Stability with LVPS cycling
7147 STIS Fine Corrector Alignment with CCD
7148 STIS CCD Target Acquisition Workout
7151 STIS CCD V2V3 Aperture Verification
7159 NUV MAMA Dark Current vs. Time from SAA
7160 CCD Reconfiguration Effects