STScI

Space Telescope Imaging Spectrograph Instrument Handbook for Cycle 14

TOC PREV NEXT INDEX PDF

F25CN182-NUV-MAMA


Description

The F25CN182 filter with the NUV-MAMA provides medium bandwidth imaging of the continuum near 1900 Å.

Recommended Uses

Continuum filter for C III].

Pivot (Å) FWHM (Å)
AB mag zeropoint
Speak
B
R80 (arcsec) Flux in central pixel
1982.0
514.2
21.478
2.59e+13
627.6
0.23
10%

Figure 14.61: F25CN182 NUV-MAMA Integrated System Throughput and Redleak


 

Table 14.24: Throughput and Sensitivity for F25CN182 NUV-MAMA
l
Sensitivity
Throughput %
1300.
7.97E11
0.03
1400.
1.60E12
0.05
1500.
2.68E12
0.08
1600.
5.37E12
0.15
1700.
9.95E12
0.26
1800.
1.49E13
0.36
1900.
2.03E13
0.47
2000.
2.51E13
0.55
2100.
2.41E13
0.50
2200.
1.83E13
0.37
2300.
1.24E13
0.24
2400.
8.29E12
0.15
2500.
5.74E12
0.10
2600.
4.18E12
0.07
2700.
3.17E12
0.05
2800.
2.46E12
0.04

Figure 14.62: Point Source S/N vs. V+AB for the F25CN182 NUV-MAMA mode. Curves are labeled by required exposure time (sec).


 
Figure 14.63: Extended Source S/N vs. V+AB for the F25CN182 NUV-MAMA mode. Top curves are for an area of 0.2 arcsec2; bottom curves are for 1 arcsec2. Average sky assumed. Curves are labeled by required exposure time (sec).


 

Table 14.25: Radial Profile for F25CN182*
Radius
 
Fraction of Energy Encircled
Pixels
Arcsec
Intensity
1
0.024
4.177e-02
0.179
2
0.037
2.686e-02
0.302
2
0.049
1.620e-02
0.422
3
0.073
5.757e-03
0.565
4
0.098
2.720e-03
0.647
5
0.122
1.425e-03
0.700
10
0.245
2.600e-04
0.810
15
0.367
1.234e-04
0.876
20
0.490
6.357e-05
0.925
25
0.613
3.483e-05
0.956
30
0.735
2.099e-05
0.979
40
0.980
2.113e-06
0.999

* See STIS ISR 2003-01.

Figure 14.64: Point Source Encircled Energy for F25CN182 NUV-MAMA


 
Figure 14.65: Point Source Intensity vs. Radius for F25CN182 NUV-MAMA


 

TOC PREV NEXT INDEX PDF
Space Telescope Science Institute
http://www.stsci.edu
Voice: (410) 338-1082
help@stsci.edu