Space Telescope Science Institute  52X2E1, 52X2E2, and 52X2D1 Pseudo-apertures 0.2X0.06 Aperture

52X0.2F1 Aperture


Description

The same physical aperture as the 52X0.2 but used at the position of the smaller of the two fiducials. The fiducial bar can be used for spectroscopic coronagraphic observations. The throughput for the unocculted 52X0.2 aperture is given below.

Special Considerations

Observations using this slit do not need to be preceded by a PEAKUP.

Table 13.23: 52X0.2 Throughputs
% Throughput
1200
65.3
1600
73.1
2000
77.0
2400
80.2
2800
82.2
3200
83.6
3600
84.6
4000
85.6
4400
86.5
4800
86.7
5200
86.9
5600
86.8
6000
86.4
6400
85.8
6800
84.9
7200
83.8
7600
82.7
8000
81.9
8400
81.2

Projected Length (arcsec)

Aperture
CCD
MAMA (M-modes)
MAMA (L-modes)
Width (arcsec)
52X0.2F1
52.0
28.0
25.0
0.2
Fiducial
0.5
0.5
0.5
0.2

Figure 13.70: 52X0.2 Aperture Throughput as a Function of Wavelength

 